CARDONE Reman Mass Air Flow Sensor P/N:74-50047
A1 CARDONE 74-10065 mass air flow sensor for the 1999-2000 Volvo S70 5-cylinder 2.4L and other vehicles measures the air entering the engine. This remanufactured unit feeds readings to the engine control management system.
A failing mass air flow sensor can show up as hesitation, stalling, poor fuel economy or poor engine performance. These signs alone do not prove the sensor is at fault, since an intake air leak can cause similar trouble, so find the cause before replacing it.
A wide range of Acura, Lexus, Toyota and Volvo models are listed for this sensor, including the 1999-2000 Volvo V70 5-cylinder 2.4L. As a mass air flow sensor for the 1999 Volvo C70 5-cylinder 2.3L, it takes one per car, and this listing is a single sensor. If your car is not named here, look for it in the "Vehicles it fits" section.
Fit and size
Build and materials
One mass air flow sensor and one instruction sheet. The mounting hardware, mounting bracket and wiring harness are not included, so plan on new hardware rather than reusing the old.
Interchange: 37980P1RA01 · 12756367 · 2225046040 · 1275636 · 12756360
Product information is for general reference and may contain errors. See our Disclaimer.
This part cross-references / interchanges with the following part numbers:
Is this the V70 mass air flow sensor for a 1999-2000 Volvo V70 5-cylinder 2.4L?
Yes. A1 CARDONE 74-10065 is listed for the 1999-2000 Volvo V70 5-cylinder 2.4L, and that car takes one sensor.
Is this the Volvo S70 mass air flow sensor for 1999-2000 models with the 5-cylinder 2.4L?
Yes. A1 CARDONE 74-10065 is listed for the 1999-2000 Volvo S70 5-cylinder 2.4L. Owners of other cars can look in the "Vehicles it fits" section.
Does the 74-10065 mass air flow sensor come with a wiring harness or mounting hardware?
No. The package holds the mass air flow sensor and an instruction sheet. The wiring harness, mounting hardware and mounting bracket are not included.
How many pins does the connector on this remanufactured mass air flow sensor have?
It has one rectangular male connector with five male pin terminals. The inlet connection is 66.04 mm (2.6 in) across and the outlet is 73.5 mm (3 in).
What fails inside a mass air flow sensor?
Common causes are cracked circuit boards, burnt sensing elements, poor solder joints, deteriorated conformal coating or loose circuit board components. A scanner can read trouble codes.
No reviews yet — be the first to review this product.
Write a Review
WARNING: These products can expose you to chemicals including lead and phthalates, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.