Standard Ignition HVAC Blower Motor Resistor P/N:RU-876
Standard Ignition HVAC Blower Motor Resistor P/N:RU-876
$88.99

If a failed resistor has left your fan stuck on one speed or skipping settings, the Standard Ignition RU-876 blower motor resistor for the 2000-2002 Subaru Forester is designed to bring back variable fan-speed control for the A/C and heater. It installs as a direct-fit replacement for the 2000-2002 Subaru Forester and is built specifically for Subaru applications.

This HVAC blower motor resistor regulates the voltage sent to the blower motor, so the fan can run at the different speeds you choose on the climate controls.

  • Copper electrical connectors: Standard Ignition uses premium copper connectors for more precise resistance values. These are intended to improve resistor performance and support a longer part life.
  • HVAC system integration: Standard Ignition's research and design process aims for seamless integration with the vehicle's HVAC system.
  • Variable speed control: Designed to restore A/C and heater blower speed control, helping optimize HVAC performance and passenger comfort.
  • Tested in-house: The resistor undergoes extensive testing at Standard Ignition's facility for correct performance in all conditions.

Signs this part may need replacing: The blower may run only on its highest setting, one or more lower speeds may not work, or the fan may not run at all. A faulty switch, damaged wiring, or a failing blower motor can cause similar symptoms, so diagnose the circuit before you replace the resistor.

See the Buyer's Guide tab for engine and application details.

Interchange: RU1566 · JA1411 · BR776 · 72024FC000

This part cross-references / interchanges with the following part numbers:

RU1566, JA1411, BR776, RU-876, 72024FC000

Frequently Asked Questions

What does a blower motor resistor do?

It controls the voltage sent to the blower motor, which lets the fan run at the different speeds you select for the A/C and heater.

Will the RU-876 fit my 2000-2002 Subaru Forester?

It is listed as a direct-fit replacement for the 2000-2002 Subaru Forester. The Buyer's Guide tab shows the full application details.

What are the signs of a failing blower motor resistor?

Common signs are a blower that works only on high, missing lower speeds, or no fan at all. A bad switch, wiring, or motor can cause similar symptoms, so diagnose the circuit first.

What sets this Standard Ignition resistor apart?

It uses premium copper electrical connectors for more precise resistance values. It is also tested at Standard Ignition's facility for correct performance in all conditions.

Which part numbers does the RU-876 interchange with?

It cross-references RU1566, JA1411, BR776, and 72024FC000.